A Guide to Global Medical Device Labeling Requirements

Clear and compliant labeling is essential for protecting patients and securing access to global markets. Labels provide instructions for safe use, enable tracking from production to patient, and show that a device meets regulatory expectations.

As manufacturers expand into new countries, they face different and frequently changing labeling rules. Meeting the standards in one region does not guarantee approval in another, which can lead to delays, recalls, or legal issues.

This guide explains what medical device labeling involves, outlines key requirements across markets, and shows how manufacturers can stay compliant to reduce risk and achieve faster, successful market entry.

What Is Medical Device Labeling?

Medical device labeling refers to all written, printed, or graphical information provided with a device, whether on the packaging, in inserts, in the Instructions for Use (IFU), or in digital formats. Its purpose is to ensure that clinicians, technicians, and patients can use the device safely and effectively.

Most regulators expect labeling to cover several essential components, including:

  • Device name and intended use: A clear description of what the product is and the purpose it serves.
  • Instructions for Use (IFU): Step-by-step directions for operation, maintenance, contraindications, and proper disposal.
  • Safety warnings and symbols: Hazard information communicated through recognized standards such as ISO 15223-1 and ISO 20417.
  • Manufacturer and importer details: Names, addresses, authorized representatives, and contact information.
  • Unique Device Identification (UDI) and barcodes: Tools that help identify and track medical devices for recalls, reporting, and overall tracking.
  • Storage and handling information: Requirements related to temperature, sterility, shelf life, and environmental limits.

Global Medical Device Labeling Requirements by Region

Understanding labeling requirements in major markets is essential for global regulatory approval. Although the purpose of labeling is consistent worldwide, each region sets its own rules for language, formatting, symbols, and traceability. 

Below is an overview of the key expectations in the United States, the European Union, and China.

United States – FDA

In the United States, the Food and Drug Administration (FDA) sets labeling rules through 21 CFR Part 801 and manages the UDI system under 21 CFR Part 830. These regulations require manufacturers to label devices clearly and assign identifiers that make them easier to track and monitor for safety purposes.

Manufacturers are expected to comply with several core requirements:

  • UDI: Devices must carry a scannable Unique Device Identifier on the product and packaging, with corresponding data submitted to the FDA’s GUDID database.
  • Language and formatting: Labels must be in clear, readable English, with adequate contrast, durable placement, and legible typography. Any symbols used must be explained unless they are already widely recognized.
  • Digital labeling: Electronic IFUs are allowed for specific device categories, provided users can reliably access them and version control is maintained.

European Union – MDR/IVDR

The European Union regulates medical devices and in vitro diagnostics under a modern, comprehensive framework established by the Medical Device Regulation (MDR) (EU 2017/745) and In Vitro Diagnostic Regulation (IVDR) (EU 2017/746). These regulations set strict rules for clinical evidence, post-market monitoring, and tracking devices throughout their lifecycle.

Key expectations include:

  • Language: Labeling must be translated into the official language(s) of every Member State where the device will be sold.
  • Symbols and content: The EU emphasizes harmonized symbols and clear safety communication, citing standards such as EN ISO 15223-1 and ISO 20417.
  • UDI and EUDAMED: Devices require a UDI, and manufacturers must register key information in EUDAMED.
  • User comprehension: Regulators assess whether the intended users, including clinicians, technicians, or patients, can easily understand the content.

China – NMPA

China’s National Medical Products Administration (NMPA) maintains its own labeling standards with an emphasis on linguistic accuracy and cultural clarity.

Expectations include:

  • Language: All labeling, including packaging and IFUs, must be written in Simplified Chinese.
  • Terminology: Manufacturers must use approved medical terms and avoid literal translations that could cause confusion.
  • Regulatory submission: Labeling forms part of the device registration dossier and is reviewed for accuracy, completeness, and alignment with the approved technical documents.
  • Digital elements: QR codes and other traceability features are widely used and must be validated to ensure correct and durable performance.

Also Read: The Ultimate Guide to Medical Device Registration in China

Best Practices for Labeling Compliance

The following practices help manufacturers build labeling systems that pass audits, support quicker market entry, and maintain quality.

1. Use Professional Translation and Localization

It’s important to work with professional medical device translators who understand regulatory expectations, device classifications, and clinical terminology. These specialists collaborate with subject-matter experts and regulatory reviewers to ensure that every label is accurate, consistent, and culturally clear. This level of expertise reduces rework, minimizes audit findings, and shortens the path to market.

2. Maintain Terminology Consistency

Create a central glossary that standardizes key terms across IFUs, packaging, and technical documentation. Translation memory tools and terminology management systems help maintain consistent phrasing across products and languages. 

Also, use formal change controls to manage glossary updates. This ensures that approved terms remain aligned across all materials.

3. Adapt Symbols and Formatting

Verify that your symbols follow recognized standards such as ISO 15223-1 and ISO 20417. Also, confirm that formatting, such as font size, contrast, layout, and icons, meets the expectations of each target market. 

Labels should remain legible and durable under real conditions, including sterilization, moisture, and abrasion. All validation activities should be documented within the design history file

4. Implement Review Workflows

Build a structured review process that includes regulatory, quality, linguistic, and design checks. Digital document control systems are essential for managing versions, audit trails, and packaging artwork. Any labeling update should align with risk management files and post-market surveillance data to maintain consistent information across the product lifecycle.

5. Stay Updated on Regulations

Regulatory requirements change regularly, and your labeling must always align with the latest. Monitor updates that affect content, UDI obligations, and post-market expectations. Incorporate routine update checkpoints into your product lifecycle and submission planning. When applicable, prepare documents in formats that support eCTD submission, as this can streamline review and maintain consistency across markets.

Conclusion

Medical device labeling is one of the most demanding parts of global compliance because each major market sets its own rules for language, symbols, UDI, and readability. Meeting these requirements takes more than correct wording. It depends on clear, accurate, multilingual labeling supported by reliable processes.

When manufacturers invest in structured workflows that bring together professional translation, controlled terminology, consistent symbols and formatting, formal reviews, and ongoing regulatory monitoring, they reduce risk and ensure safe and timely product launches worldwide.

At EC Innovations, we provide medical device translation services that help companies create clear, accurate, and compliant labeling for global markets. Our team provides accurate, compliant translation and labeling support for global markets. Contact us if you need help preparing labels, IFUs, or documentation for your next submission or market launch.

Scroll to Top